EP3300 TLV series off grid solar system inverter

Short Description:

This split phase inverter EP3300 TLV series, capacity from 1KW-6KW, DC 12V/24V/48V, it’s applicable to 110VAC/120VAC markets demands, which matches AC 110VAC/120V single phase, or two phase 110VAC/120V 120V/240V; In LCD display, you can set output voltage, frequency, charging voltage, charging current to design best use based on different loads applications; meanwhile, you can also connect extra solar charger controller to build a solar home system, take use of sunshine freely and save electricity bills.


Product Detail

Product Tags

EP3300 TLV (1)
1233

Features

 Pure sine wave output, split phase HOT1+ N + HOT2 available, 120VAC/220VAC

 MFD (multi-function display) & Friendly user interface

 3 Steps optimizing charge for battery pack

 Overload and short-circuit protection

 Settable: charging/charging current, utility/Battery priority, utility input wide/

 narrow range

 Inverter voltage can be set to 100V/110V/120V

 Inverter frequency can be set to 50/60Hz

PRODUCT FEATURES

—— Smart & Intelligent Features ——

Pure sine wave output

Two pure sine wave AC 110V/120V output(Split Phase)

EP3300 TLV (6)

Smart Battery Chargers - 3 steps optimizing battery charge

Boost CC Stage: If A/C input is applied, the charger will run at full current in CC mode until the charger reaches the boost voltage.

Boost CV Stage: the charger will keep the boost voltage in Boost CV mode until the charge current less 6A continue 1minute or keep the boost voltage time more than 2hours. Then drop the voltage down to the float voltage.

Float Stage: In float mode, the voltage will stay at the float voltage. If the A/C is reconnected , the charger will reset the cycle above.

EP3300 TLV (7)

Easy to read all working modes and parameters in LCD

Line Mode

Input power will provide energy to load directly. And it will charge the battery at the same time. If voltage of input power is outside of section, the machine will switch to battery mode.

EP3300 TLV (8)

Battery Mode

The unit will get energy from battery and provide to load.

EP3300 TLV (9)

Fault Mode

If any fault has happened, the machine will enter to the mode. And fault code is displayed on the LCD.

EP3300 TLV (10)

Smart setting to make inverter work more efficiency

A: save mode switch to save more power:

EP3300 TLV (11)

B: Power Source - Battery/ AC Priority Setting:

EP3300 TLV (12)

UTI, utility priority (default); SBU, battery priority; Setting as below:

EP3300 TLV (13)

 PRODUCT DETAILS

—— Must help you control every detail ——

① Switch on/off

② Page up

③ Menu

④ AC Status LED

⑤ Inverter Status LED

⑥ LCD Setting

⑦ Fault Warning LED

⑧ Enter and confirm

⑨ Page down

⑩ Battery -/+

⑪ BTS

⑫ AGS

⑬ Remote Panel

⑭ USB

⑮ Fan

⑯ AC Input Protect

EP3300 TLV (14)
EP3300 TLV (16)
EP3300 TLV (14)

① AC OUTPUT:

HOT1 - HOT2 240VAC/220 VAC/230VAC

② AC OUTPUT1:

HOT1 - N 120VAC/110 VAC/115VAC

③ AC OUTPUT2:

HOT2 - N 120VAC/110 VAC/115VAC

④ AC INPUT:

HOT1 - HOT2 240VAC/220 VAC/230VAC

⑤ 5.15A MAX JFCI Output

110V/115V/120V Socket, 15A MAX

EP3300 TLV (15)

PRODUCT SYSTEM CONNECTION

—— Inverter + Solar Charge Controller + Battery + Solar Panels + Grid +  Application Loads ——

EP3300 TLV (5)

EP3300 TLV, split phase inverter, it can support different loads with it’s inbuilt pure copper transformer, like laptop, TV, Air-conditioner, fridge etc... Normally this inverter work with battery as back up system to meet different power demands in daily life; it can also connect extra MPPT/PWM solar charge controller, then work as an solar inverter system, use sunshine energy to save electricity bills.

PRODUCT PARAMETERS

—— Make sure each parameter is true ——

Model

EP33-

1012

TLV

EP33-

1024

TLV

EP33-

1512

TLV

EP33-

1524

TLV

EP33-

2012

TLV

EP33-

2024

TLV

EP33-

3024

TLV

EP33-

3048

TLV

EP33-

4024

TLV

EP33-

4048

TLV

EP33-

5048

TLV

EP33-

6048

TLV

Inverter

Output

Rated power

1KW

1.5KW

2KW

3KW

4KW

1KW

1.5KW

Power factor

1

Wave form

Pure sine wave / Same as input wave form (bypass mode)

Output voltage RMS

110V /120VAC (220V / 230V / 240VAC)

Output frequency

50Hz or 60Hz (±0.3Hz) (can be set)

Overload protection Output short circuit

Breraker + software protection

Inverter efficiency (peak)

>80%

Overload

100%<Load<110% (alarm 5min then stop output ) / 110%<Load<125% (alarm 60s then stop output) /

 Load > 125% (alarm 10s then stop output )

Surge rating

3000VA

4500VA

6000VA

9000VA

12000VA

15000VA

18000VA

Capable of starting electric motor

1P

1P

1.5P

1.5P

2P

3P

Battery

Battery voltage

12VDC/24VDC

24VDC/48VDC

48VDC

Minimum start voltage

11VDC/22VDC/44VDC

Low battery voltage cut off

(Low voltage fault code04)10/10.5/11V for 12V mode (*2 for 24VDC / *4 for 48VDC)

Low battery voltage alarm

Add 0.5V / battery:(Low battery alarm one second one time) (10/10.5/11V)+0.5VDC for 12V mode (*2 for 24VDC / *4 for 48VDC)

High battery voltage alarm

Add 1V/battery:(High battery one second one time /after 30s fault 03) (13.8-14.5V)+1V for 12V mode (*2 for 24VDC/*4 for 48VDC)

Save mode

Loads ≤ 40W (110V) / 80W (220V)

AC Input

Mode

Input waveform

Pure sine wave

Nominal input voltage

220Vac / 230Vac / 240Vac

Max input voltage

270Vac MAX

Input frequency

50Hz / 60Hz (auto sensing)

Efficiency (AC mode)

>95% (load, full battery)

Transfer time AC to DC

15ms(max)

Charge

Mode

Boost voltage

14.1V(Default) Range of adjustment 13.8-14.5V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)

Float voltage

13.5V(Default) Range of adjustment 13.5-13.7V / *2 for 24VDC / *4 for 48VDC (Regulation step 0.1V)

12V

30A

45A

60A

\

\

\

\

24V

20A

25A

30A

40A

60A

\

\

48V

\

\

\

20A

30A

35A

40A

Min charge current 10A. Change by every 5A

Dimensions

Dimensions (W*H*D)

277*196*466mm

277*186*621mm

Ship Dimensions (W*H*D)

376*306*592mm

376*296*747mm

Warranty

One year (standard), 2 years optional (IP20)

 


  • Previous:
  • Next:

  • Related Products